Command
This field contains the index in the command list for the first
value in the file. This field will have a value of 0 to
(MaxCommands-1).
Each word of this area contains the last error value recorded
for the command. The command index of the first value (offset
4) is specified in word 3 of the block. The number of valid
command errors in the block is set in word 2 of the block.
Refer to the command error list to interpret the error codes
reported.
This field contains the value of 9950 identifying the block type
to the PLC.
Block 9958: Binary Input Event With Calendar Time
Block identification code 9958 sends a set of binary input events with calendar time to the
module. The following table lists the block format of Binary Input Event Request sent to the
module from the ControlLogix processor.
This field contains the value of 9958 identifying the event block
to the module.
This field contains the number of events contained in the
block. Valid values for this field are 1 to 24.
This field is used to hold the sequence counter for each 9958
block transfer. This is used to synchronize and confirm receipt
of the block by the module.
Data point in the DNPNET binary input database represented
by the event.
Regardless of the Class defined for the given point number,
this will be the Class of the event. (1, 2, or 3)
Value of the point, 0 or 1, of bit 0 of this 16-bit word. All other
bits are ignored.
Year of the event timestamp
Month of the event timestamp
Day of the event timestamp
Hour of the event timestamp
Minute of the event timestamp
Seconds of the event timestamp
Milliseconds of the event timestamp
Ten words of data for Event #2.