Prosoft-technology PLX8X-MNET-61850 Manual do Utilizador Página 147

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 228
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 146
PLX8x-MNET-61850 Communication Gateway Reference
Modbus TCP/IP to IEC 61850 User Manual
ProSoft Technology, Inc. Page 147 of 228
May 14, 2014
6.4.1 Application Association Model
This section describes the gateway’s implementation of IEC-61850-72- Clause 7:
Application association model. This clause describes how the association
between two devices is achieved: TWO-PARTY-APPLICATION-ASSOCIATION
and/or MULTICAST-APPLICATION-ASSOCIATION. Both types are used.
Two Party Messaging
Two Party messaging is the most common type of messaging our IEC 61850
driver performs. The following diagrams show the execution of two-party
messages, and their associated abort sequence. In the diagrams, the IEC 61850
Client driver is the Client. This information has been taken directly from the IEC
61850 standard.
Vista de página 146
1 2 ... 142 143 144 145 146 147 148 149 150 151 152 ... 227 228

Comentários a estes Manuais

Sem comentários