Prosoft-technology 5201-DFNT-104S Manual do Utilizador Página 121

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 157
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 120
Reference 104S v2 ProLinx Gateway
Protocol Manual (Firmware v2.xx)
ProSoft Technology, Inc. Page 121 of 157
March 19, 2010
5.2.6 Get Time Command Block
This functionality allows a remote node to retrieve the clock data from the
ProLinx gateway
Request Block
The following table describes the structure of the Get Time command block.
Start Word End Word Description
0 0 Block ID1 (Command Request Without Response)
1 1 200 or 201 = Get Time (Block ID2)
2 2 Year
3 3 Month
4 4 Day
5 5 Hour
6 6 Minutes
7 7 Seconds & milliseconds
8 98 Reserved for future use
99 99 Block ID1 (Command Request Without Response)
Response Block
Start Word End Word Description
0 0 200 or 201 = Get Time (Block ID2)
1 1 Block ID1 (Command Request Without Response)
2 2 Year
3 3 Month
4 4 Day
5 5 Hour
6 6 Minutes
7 7 Seconds & milliseconds
8 98 Reserved for future use
99 99 200 or 201 = Get Time (Block ID2)